Customization: | Available |
---|---|
Customized: | Customized |
Brand: | Skyray |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rail transit fiber optic temperature controller | Fluorescent fiber optic sensing probe | |||
Ambient temperature: | -20ºC~+55ºC | Material: | No metal material, quartz fiber | |
Ambient humidity: | < 95% (25ºC) | Probe size: | 3mm in diameter; Standard equipped with 3M(Customizable length) |
|
Working voltage: | AC 220V (+10%,-15%) | Immune electromagnetic interference Withstand power frequency voltage 100KV |
||
Working frequency rate: | 50Hz OR 60Hz(±2Hz) | |||
Range of measurements: | -40.0ºC~200.0ºC | |||
Measurement accuracy: | ±1%FS | |||
Resolution ratio: | 0.1ºC | |||
Fan output total capacity: | 9A/250VAC | |||
Control output capacity: | 5A/250VAC;5A/30VDC(resistivity) |
Production standards | JB/T7631-2005"Electronic temperature controller for Transformers"Industry standards |
Adoption of accreditation standards: | ISO9001:2008International Quality Management System Certification |
Pass the test standard: | IEC61000-4:1995 International standard |
GB/T17626-2008"Electromagnetic compatibility test and measurement techniques"standard |
Special temperature controller for rail transit |
1.Monitor up to three dry-type transformer windings; |
2.Built-in fan control, fan exerciser; |
3.Each temperature sensor has temperature compensation function |
4.When the monitor is turned off, the temperature value can be saved. |
5.LCD liquid crystal display, LED display lamp, operation button; |
6.Clock function; |
7.Alarm function for transformer door cabinet opening; |
8.1 pair of over-temperature alarm terminals (1 normally open, 1 normally closed); |
9.3 sets of over-temperature trip terminals (3 normally open and 3 normally closed) are provided; |
10.1 set of fan remote transmission nodes (1 normally open, 1 normally closed); |
11.1 set of temperature controller power off alarm contacts (1 normally open, 1 normally closed); |
12.1 set of temperature controller fault alarm contacts (1 normally open, 1 normally closed); |
13. RS485 communication function, MODBUS-RTU protocol; |
Custom function |
1.According to customer demand, provide 4 channel 4~20mA analog current output function;
|
2.According to customer requirements, provide fan fault judgment function, provide two fan fault alarm contacts ; |
3.1-8 channel optical fiber temperature measurement |
4.Many kinds of communication: industrial networking module, ethernet communication, profibus communication module and so on. |
5.According to customer needs,provide alarm function for winding and iron core temperature rise rate. |